ST05 Features
-
The sensor signal output is shown in real time on the bar graph, while a 2 digit alphanumeric display shows the sensor output cross count per second.
-
By pressing the ‘Test’ button and performing a snap throttle acceleration of the engine, it tests the response time of the sensor and shows a pass or fail result within seconds.
-
Two buttons allows for simulation of rich or lean conditions to monitor response of the engine control module.
-
Advanced connection detection: The ST05 automatically detects common wire misconnections like ground, heater wires, disconnected test leads, reversed polarity etc. and displays these on the alphanumeric display.
-
It only requires the connection of two probe clips to the oxygen sensor wires, and the selection of the oxygen sensor type.
Simple and flexible to use
-
Sensor can be tested on or off the vehicle
-
Does not require special setups or in depth knowledge to use
-
Provides instant readings and testing capabilities of the output of the sensor
-
Diagnoses “lazy” (slow response) sensors, which may not set DTCs, but cause drivability problems
-
Excellent preventive maintenance tool, to diagnose sensors that need to be replaced before they set DTCs or completely fail
-
Ruggerized electronics make it almost impossible to damage the instrument, even if wrongly connected
-
No software to upgrade.
Technical Specifications
-
Display:
-
2 digits LED alphanumeric display
-
20 segments LED bargraph with 0 to 1 Volt or 0 to 5 Volt ranges
-
-
Cross Count: 0.1 to 10 CPS
-
Response test: <100 ms Pass +/- 5 ms, >100 ms Fail +/- 5 ms
-
Test leads: 2 wire piercing alligator clips, and 6.5 ft cables
-
Power Source: One standard 9 Volt alkaline battery type NEDA 1604 IEC 6F 22
-
Battery life: Approx. 25 hrs, with low battery indicator and auto power
-
Physical dimensions (including holster): 6" (H) x 4" (W)x 1.5" (D) (158 x 100 X 37 mm)
-
Weight: Approximately 14 Oz. or 406 gr. (including battery)
Electrical Specifications
-
Input Range: 0 to 5 Volt
-
Input Protection: +/- 48 VDC Max, current limited
-
Auto Detection: Detects reversed polarity, ground, heater and open connection
Applications:
-
Test zirconium sensors
-
Test titanium 1 Volt sensors
-
Test titanium 5 Volt sensors
-
Test 1 to 4 wires sensors (heated and unheated)
-
Simulate rich and lean sensor output
-
Test sensor response time
ST05 Includes:
-
ST05
-
Two piercing clips with 6 ft. cables
-
Protective rubber holster
-
Polypropylene carrying case
-
1 x 9 Volt alkaline battery
-
User’s Manual